Electrochemical detection of NOx gas based on disposable paper-based analytical device using a copper nanoparticles-modified screen-printed graphene electrode.

Clicks: 226
ID: 32928
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #55 of 85 articles by views in Biosensors & bioelectronics

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A disposable gas-sensing paper-based device (gPAD) was fabricated in origami design which integrates the gas adsorbent and the electrochemical detection zone in a single device. The gPAD for the determination of NOx gas uses a screen-printed graphene electrode modified with copper nanoparticles (CuNP/SPGE) to achieve high sensitivity and selectivity. The gPAD detects both, NO and NO (as NOx) with same current responses. The measurement could be performed directly through differential pulse voltammetry (DPV) with a detection limit as low as 0.23 vppm and 0.03 vppm with exposure times of 25 min and 1 h, respectively. The reproducibility in terms of relative standard deviation was less than 5.1% (n = 7 devices) at 25, 75 and 125 vppm NO and the life-time of this device was more than 30 days. The gPAD was applied to detect NOx in air and exhaust gases from cars. In comparison with spectrophotometry, there are no significant differences between both methods using a paired t-test of the results on a 95% confidence level. The designed gPAD can provide a new template model for other gas sensors with features of disposability and portability for fieldwork analysis at low cost.
Reference Key
pungjunun2019electrochemicalbiosensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Pungjunun, Kingkan;Chaiyo, Sudkate;Praphairaksit, Narong;Siangproh, Weena;Ortner, Astrid;Kalcher, Kurt;Chailapakul, Orawon;Mehmeti, Eda;
Journal Biosensors & bioelectronics
Year 2019
DOI
S0956-5663(19)30685-2
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.