Transportability of an AI-ECG Model for Structural Heart Disease: External Validation and Recalibration of Echonext-Mini in MIMIC-IV

Clicks: 27
ID: 329220
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #7 of 80 articles by views in European Heart Journal - Digital Health

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Structural heart disease is often underdiagnosed, and echocardiography is limited by access and referral thresholds. Artificial-intelligence electrocardiography may identify echocardiographically defined structural heart disease. EchoNext-Mini is a released AI-ECG model, accompanied by a benchmark dataset, that detects a composite structural heart disease outcome and component conditions from 12-lead electrocardiogram waveforms together with age, sex, and electrocardiographic measurements. We assessed its transportability and recalibration. Methods We linked electrocardiograms from MIMIC-IV to subsequent transthoracic echocardiograms, including adults whose electrocardiogram preceded an eligible echocardiogram within one year, one per patient. Labels were mapped to structured echocardiographic fields using original thresholds where available, harmonized definitions otherwise. The released model was applied without retraining to this cohort and its benchmark test set, then assessed for discrimination, calibration, recalibration, subgroups, and label sensitivity. Results Among 45,878 patients, structural heart disease prevalence was 47.2%. Composite area under the receiver operating characteristic curve was 0.790 (95% confidence interval, 0.786 to 0.794), against 0.820 on the benchmark test set. Component values ranged from 0.679 for left ventricular wall thickness to 0.837 for right ventricular dysfunction. The composite was near-calibrated (slope, 0.93), whereas all component probabilities overestimated risk in both settings. A shift derived from the released training prevalences, requiring no local outcome data, largely corrected it. Conclusions EchoNext-Mini transported to MIMIC-IV with composite discrimination within the published external-validation range. Component probabilities behaved as ranking scores rather than absolute risks, a property of the released model rather than the validation setting, and require adjustment before use as risk estimates.
Reference Key
openalex_W7213625455 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Digital Health
Year 2026
DOI
10.1093/ehjdh/ztag147
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.