Characterization of CsI(Tl) and LYSO(Ce) scintillator detectors by measurements and Monte Carlo simulations.

Clicks: 317
ID: 32894
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #9 of 55 articles by views in Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In this study, we investigated the performance of two cuboid scintillation detectors: thallium-activated cesium iodide [CsI(Tl)] and cerium-doped lutetium yttrium orthosilicate [LYSO(Ce)]. The CsI and LYSO crystals were 5 mm thick with an active area of 10 mm × 10 mm. The LYSO scintillator is characterized by its high stopping power and non-hygroscopicity (neither packaging nor light guide are required). Nevertheless, the main disadvantages of LYSO detectors are a lower light output (32 photons/keV) and an intrinsic radioactivity caused by the β decay of Lu (half-life 3.78 × 10 years). In contrast, CsI crystals present a relatively high light output (54 photons/keV) allowing better energy resolution; however, the drawback of a CsI detector is low detection efficiency. First, we measured the photon detection efficiency of each scintillator in the photon energy range of 60-1332 keV using radioactive sources. Second, we computed detector efficiencies using the Monte Carlo codes MCNP and Geant4. A comparison between simulated and measured efficiencies showed a good agreement. This comparison confirmed the validity of the mathematical models developed for the two scintillation detectors CsI(Tl) and LYSO(Ce) under investigation.
Reference Key
mouhti2019characterizationapplied Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Mouhti, I;Elanique, A;Messous, M Y;Benahmed, A;McFee, J E;Elgoub, Y;Griffith, P;
Journal Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
Year 2019
DOI
S0969-8043(19)30140-X
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.