Full-scale e-bus fire in a tunnel and vehicle—infrastructure collaborative suppression using water mist

Clicks: 15
ID: 328575
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #22 of 44 articles by views in Transportation Safety and Environment

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Electric-bus fires have become a critical safety issue in enclosed tunnel environments. Conventional fire-extinguishing methods may provide insufficient direct cooling of battery packs and may not maintain thermally tenable conditions in passenger compartments. This study reports a 1:1 full-scale electric-bus fire test in a 330 m-long test tunnel to evaluate a vehicle–infrastructure collaborative suppression (VICS) strategy that combines targeted onboard cooling with tunnel-environment shielding using high-pressure water mist (HPWM). An array of 106 thermocouples was deployed to measure the three-dimensional thermal environment and assess suppression performance. The passenger-compartment temperature remained below the 60°C thermal tenability criterion throughout the test, with a maximum measured breathing-zone temperature of 54.3°C. The peak tunnel-ceiling temperature was limited to 42.4°C, and the measured radiant heat flux remained far below levels associated with sustained structural damage, except for a short local transient peak. Energy-balance analysis suggested a suppressed peak fire intensity of approximately 2 MW and indicated that water-mist evaporation absorbed a substantial fraction of the released heat. This work provides full-scale experimental evidence and a benchmark dataset for fire-safety management of electric buses in tunnels.
Reference Key
openalex_W7212355072 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Transportation Safety and Environment
Year 2026
DOI
10.1093/tse/tdag047
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.