Fibrillar haemostatic agents mimicking nodal recurrence after thoracic surgery: a cohort study

Clicks: 24
ID: 328279
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #10 of 147 articles by views in Interdisciplinary CardioVascular and Thoracic Surgery

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 147 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
OBJECTIVES: Fibrillar haemostatic agents are widely used to control bleeding. However, they may persist post-operatively and induce a foreign body reaction or mimic lymph-node recurrence on different imaging modalities. METHODS: This retrospective cohort study included 11 patients who underwent thoracic surgery for lung or mediastinal malignancy with intraoperative fibrillar haemostatic material and subsequently developed imaging findings suspicious for malignancy recurrence. Patient demographics, tumour characteristics, surgical details, and fibrillar usage were recorded. Imaging findings across CT and PET-CT were analysed. Clinical outcomes, including follow-up interventions and histopathological results, were reviewed. RESULTS: The mean time from surgery to detection of a suspicious lesion was 9.7 months (range 2-24). PET-CT was the follow-up modality in 81.9% of cases, demonstrating increased FDG uptake in 7/9 cases, with SUVmax ranging from 2.0-14.4. FDG uptake and SUVmax values overlapped substantially between benign and malignant lesions, with no threshold reliably distinguishing the two. In all cases, lesions were located at or adjacent to prior surgical sites corresponding to fibrillar placement. 10/11 patients (90.9%) required active intervention beyond imaging surveillance. Histopathology showed benign foreign-body reaction in 7/11, malignant recurrence in 2/11, and both in 2/11 (malignancy present in 4/11 overall). CONCLUSIONS: Fibrillar residues are a recognised and clinically significant mimic of nodal recurrence across imaging modalities, particularly on PET-CT. Recognition of characteristic imaging features and correlation with surgical history are essential to avoid unnecessary invasive procedures. Where tissue diagnosis is required, endobronchial ultrasound (EBUS)-guided biopsy is recommended as the preferred first-line approach before surgical re-intervention.
Reference Key
openalex_W7212025709 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Interdisciplinary CardioVascular and Thoracic Surgery
Year 2026
DOI
10.1093/icvts/ivag245
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.