Y-incision aortic annular enlargement using the arc patch modification: a step-by-step tutorial

Clicks: 12
ID: 328162
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #34 of 50 articles by views in Multimedia Manual of Cardio-Thoracic Surgery

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Aortic annular enlargement is an important adjunct to aortic valve replacement in patients with a small aortic annulus and restricted aortic root anatomy. The Y-incision technique facilitates implantation of a larger prosthetic valve, reducing the risk of prosthesis-patient mismatch and improving postoperative haemodynamics. This video tutorial demonstrates Y-incision aortic annular enlargement combined with bioprosthetic aortic valve replacement in a 67-year-old woman with symptomatic severe aortic stenosis and a severely restricted aortic root anatomy. Preoperative imaging revealed a 19 mm aortic annulus, small aortic root dimensions and a narrow sinotubular junction. Following extensive aortic root mobilization, a Y-shaped incision was extended through the aortomitral curtain and reconstructed using an arc-shaped patch modification to facilitate annular, root and sinotubular junction enlargement. The enlarged annulus allowed implantation of a 23 mm bioprosthetic valve with careful commissural alignment and root reconstruction. Postoperative imaging demonstrated excellent valve position and function without paravalvular leak. Peak and mean transvalvular gradients were 14 and 8 mmHg at discharge, and remained stable at 4-month follow-up. This video tutorial highlights the key technical steps of Y-incision aortic annular enlargement and demonstrates excellent early haemodynamic results following implantation of an appropriately sized prosthesis.
Reference Key
openalex_W7212047881 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Multimedia Manual of Cardio-Thoracic Surgery
Year 2026
DOI
10.1510/mmcts.2026.076
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.