Deep Learning Based Real-Time Phase-Amplitude Correction for Phased Array Transducers in Transcranial Focused Ultrasound

Clicks: 48
ID: 327487
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #13 of 44 articles by views in journal of computational design and engineering

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Transcranial focused ultrasound (tFUS) is a non-invasive therapeutic approach for various brain disorders. However, acoustic distortions during ultrasound propagation through the skull make accurate targeting challenging. Time-reversal (TR) simulations can correct these distortions but are computationally expensive for real-time applications. The present study proposes a deep learning model that predicts the phase and amplitude of each phased-array transducer element in real time, enabling accurate patient-specific focusing at the target point. Using CT-derived skull geometry as input, the proposed model replaces computationally intensive TR simulations with direct prediction from skull geometry and spatial configuration. The model was trained using TR simulations of a 1,024-element phased array transducer system and evaluated on two unseen test skulls excluded from training. A dual-head architecture separately handles amplitude regression and phase classification, using circular soft labeling to capture phase periodicity. The proposed model achieved a circular mean absolute error of 0.28–0.42 rad in phase prediction and a relative energy error of 1.18–4.35 % in amplitude estimation. The reconstructed acoustic focus achieved peak location error of 0.61–1.46 mm, mean surface distance of 0.50–1.84 mm, and peak pressure recovery of 33–141 % across three target regions. Compared to conventional TR simulations, the proposed method achieves a 4,069× speedup in pure inference and a 48× wall-clock acceleration, supporting real-time clinical deployment. These results demonstrate that skull-induced acoustic distortions can be efficiently approximated using physics-informed surrogate modeling, providing a scalable foundation for real-time patient-adaptive transcranial ultrasound systems.
Reference Key
openalex_W7207744069 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal journal of computational design and engineering
Year 2026
DOI
10.1093/jcde/qwag079
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.