Near Real-Time Multi-Class Segmentation for Intravascular Optical Coherence Tomography using Knowledge Distillation

Clicks: 13
ID: 326956
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #63 of 80 articles by views in European Heart Journal - Digital Health

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Aims Intravascular optical coherence tomography (OCT) enables high-resolution imaging of the coronary vessel wall, but manual image interpretation is time-consuming and existing automated approaches often require high computational resources and exhibit slow inference times, limiting clinical use. We developed OCT-AID-lite, a neural network for near real-time multi-class OCT segmentation leveraging knowledge distillation and semi-supervised learning to accelerate inference while maintaining segmentation accuracy. Methods and results A state-of-the-art model (OCT-AID) guided a compact U-Net–based student model (OCT-AID-lite) through knowledge distillation-based supervision. OCT-AID-lite was trained on 3,466 manually annotated and 137,961 pseudo-labeled frames after automated quality control. On 389 internal test frames, OCT-AID-lite achieved a forward-pass time of 0.10 seconds for a 540-frame pullback, compared with 24.22 seconds for OCT-AID model (p<0.01). Including pre- and post-processing, total processing time was 5.50 seconds for OCT-AID-lite, compared with 30.62 seconds for OCT-AID (p<0.01). For lipid and calcium plaque classification, OCT-AID-lite reached sensitivity/specificity of 98.1%/74.4% and 89.5%/87.5%, respectively. Pixel-wise segmentation performance on true-positive frames was high for guidewire, catheter, lumen, intima, and media (Dice: 0.79–0.99), moderate to high for sidebranch, lipid, and calcium (Dice: 0.76–0.78), and more variable for rare complex classes (Dice: 0.39–0.67). On an independent external test set, model predictions were in agreement with expert assessment. Conclusions OCT-AID-lite enables accurate OCT segmentation in near real-time, allowing efficient quantitative characterization of plaque and vessel structures.
Reference Key
openalex_W7205017263 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Digital Health
Year 2026
DOI
10.1093/ehjdh/ztag138
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.