Transjugular LuX-Valve Plus Transcatheter Tricuspid Valve Replacement for Torrential Tricuspid Regurgitation in a Patient With a Giant Right Atrium and Prior Multiple Valve Interventions: A Case Report

Clicks: 16
ID: 326955
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #235 of 408 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 408 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Transcatheter tricuspid valve replacement (TTVR) is an option for selected patients with severe tricuspid regurgitation (TR) who are at high surgical risk, but experience remains limited in those with extreme right-heart anatomy, including a giant right atrium and a markedly enlarged elliptical tricuspid annulus. Case summary A 62-year-old man was admitted with progressive dyspnoea and lower-extremity oedema (NYHA class IV). He had prior mechanical mitral valve replacement and transcatheter aortic valve replacement. Echocardiography and CTA showed torrential TR, a giant right atrium (11.59 × 7.73 cm), preserved right ventricular systolic function, and a markedly elliptical annulus with a perimeter-derived diameter of 55.5 mm. Persistent TR despite satisfactory left-sided prosthetic valve function prompted transcatheter evaluation. Redo surgery was prohibitive and transcatheter edge-to-edge repair unsuitable. The Heart Team selected LuX-Valve Plus because its leaflet graspers and septal anchor provide radial force-independent multipoint fixation. A 79.2-mm bend-point-to-annulus distance exceeded the proposed 45–70 mm range, requiring a slightly lateral jugular entry angle and complicating depth control and coaxial alignment. The mechanical mitral prosthesis limited transoesophageal echocardiography (TEE) but served as a fluoroscopic landmark; TEE and fluoroscopy enabled successful implantation. At 1 month, NYHA class improved to II, with stable prosthetic haemodynamics, no obvious transvalvular regurgitation, and trivial paravalvular leak; findings remained stable at 6–7 weeks. Discussion This case highlights the feasibility of transjugular LuX-Valve Plus TTVR in extreme right-heart anatomy and emphasizes the importance of anatomy-driven device selection, tailored delivery and imaging strategies, and individualized postprocedural management.
Reference Key
openalex_W7205017140 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag658
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.