Retrograde Transaortic Percutaneous Retrieval of a Left-Ventricularly Embolized LAmbre Occluder Followed by Same-Session Redo Left Atrial Appendage Closure: A Case Report

Clicks: 11
ID: 326945
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #321 of 407 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 407 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Left atrial appendage closure (LAAC) is an established stroke-prevention strategy for selected patients with atrial fibrillation who are unsuitable for long-term oral anticoagulation. Device embolization is rare but potentially life-threatening, particularly when the occluder migrates into the left ventricle, where it may interfere with the mitral or aortic valve apparatus or provoke ventricular arrhythmia. Case summary A 68-year-old woman with permanent atrial fibrillation, recurrent gross hematuria during anticoagulant therapy, chronic heart failure, and a high thromboembolic risk underwent LAAC under transesophageal echocardiographic guidance. Pre-procedural imaging showed a left atrial appendage ostium of 30 mm, a landing-zone diameter of 28 mm, and a depth of 32 mm. During the first deployment attempt with a 28/34-mm LAmbre occluder, the device showed insufficient anchoring and was not released. During attempted recapture and exchange, the partially deployed device embolized across the mitral valve into the left ventricular cavity, with a short self-terminating episode of ventricular tachycardia. Because the patient remained hemodynamically stable and real-time imaging showed no valvular entrapment or structural injury, retrograde transaortic percutaneous retrieval was performed using a 14-Fr steerable sheath and grasping forceps. After successful retrieval and immediate confirmation of valve integrity, a larger 32/36-mm LAmbre occluder was implanted in the same session with stable position and no residual peri-device leak. Discussion This case illustrates that, in carefully selected hemodynamically stable patients without valvular entrapment, left ventricular outflow tract obstruction, or structural injury, retrograde transaortic percutaneous retrieval of a left-ventricularly embolized LAAC device may be feasible. Same-session redo LAAC can be considered after successful retrieval when valve integrity is confirmed and the left atrial appendage anatomy remains suitable.
Reference Key
openalex_W7205009725 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag634
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.