Intraprocedural Tail-First Pulmonary Artery Migration of a Leadless Pacemaker: A Protective Sleeve–Assisted Helix-Side Retrieval Strategy: a case report

Clicks: 13
ID: 326927
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #305 of 408 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 408 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Leadless pacemaker migration into the pulmonary artery is an exceptionally rare but potentially serious complication. Tail-first (proximal helix–oriented) migration poses additional risk, as traction on the exposed helix may cause vascular injury. Case summary A 72-year-old woman with bradycardic atrial fibrillation underwent implantation of an Aveir™ VR leadless pacemaker. Immediately after device release, fluoroscopy revealed a tail-down shift suggesting inadequate mechanical engagement, accompanied by frequent premature ventricular contractions and non-sustained ventricular tachycardia, prompting immediate retrieval. During the retrieval procedure, the device became completely dislodged and migrated into the left pulmonary artery with the helix oriented proximally. In this orientation, standard docking button retrieval was not feasible. The Aveir™ retrieval catheter was advanced into the pulmonary artery, the helix was captured, and the device was enclosed within the protective sleeve before successful extraction. The new device was subsequently re-implanted at a more apical septal site, and stable fixation was achieved. Discussion In previously reported cases of pulmonary artery migration of the Aveir™ pacemaker, retrieval was performed using non-dedicated flexible sheaths and snare catheters. In contrast, this case demonstrates that advancing the dedicated retrieval system to enclose the grasped helix enabled controlled retrieval while minimizing direct contact between the exposed helix and the pulmonary arterial wall. This case also highlights that satisfactory electrical parameters alone may not guarantee adequate mechanical fixation. Although this technique may represent a practical bailout strategy when engagement of the docking button is not feasible, further clinical experience is required to establish its safety and reproducibility.
Reference Key
openalex_W7205004410 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag657
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.