Single-Session Combined Mitral Transcatheter Edge-To-Edge Repair and Left Atrial Appendage Occlusion Using a Steerable Introducer After a Mitral Repair-Oriented Transseptal Puncture: A Case Report

Clicks: 16
ID: 326906
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #234 of 408 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 408 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Combined mitral transcatheter edge-to-edge repair (M-TEER) and left atrial appendage occlusion (LAAO) may be considered in selected high-risk patients with severe mitral regurgitation (MR) and atrial fibrillation (AF). However, the optimal transseptal puncture site differs between procedures, potentially limiting the feasibility of a single-session approach. Clinical summary An 80-year-old frail woman with severe atrial functional MR, permanent AF, chronic kidney disease, and recent severe anaemia was referred for treatment. Considering the patient’s high thromboembolic and bleeding risk and overall frailty, a combined percutaneous approach was selected. A supero-posterior transseptal puncture optimized for mitral repair enabled successful M-TEER with significant MR reduction. Subsequent LAAO was challenged by suboptimal alignment with the appendage. The use of a steerable introducer restored coaxiality, allowing stable device delivery and successful deployment of a 24-mm occluder with complete sealing and no peri-device leak. Discussion This case demonstrates the feasibility of a combined one-stop strategy in frail patients at high procedural risk. It highlights the importance of procedural planning and the role of steerable delivery systems in overcoming anatomical constraints imposed by a mitral-oriented transseptal puncture, thereby facilitating successful completion of both interventions in a single session.
Reference Key
openalex_W7204993943 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag622
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.