VIsual STAndardized Quantification of LGE (VISTAQ), a contour-less method for late gadolinium enhancement quantification

Clicks: 18
ID: 326875
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #20 of 72 articles by views in European Heart Journal - Imaging Methods and Practice

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
ABSTRACT Background Late gadolinium enhancement (LGE) quantification by cardiovascular magnetic resonance is central to risk stratification in hypertrophic cardiomyopathy (HCM), yet conventional techniques require contour tracing and region-of-interest (ROI) placement, which may reduce reproducibility and increase analysis time. We developed a novel visual standardized approach, the Visual Standardized Quantification of LGE (VISTAQ), that does not require myocardial contouring, arbitrary ROI positioning, or dedicated post-processing software. Methods In this multicenter, multivendor retrospective study, LGE images from 400 patients (100 prior myocardial infarction, 250 HCM, 50 other non-ischemic heart diseases) were analyzed. VISTAQ subdivides each myocardial segment into transmural mini-segments and classifies LGE visually using predefined criteria, expressing global LGE burden as the percentage of positive mini-segments. Reproducibility was assessed in 250 patients across different observer expertise levels using intraclass correlation coefficients (ICC) and Bland–Altman analysis. In 100 HCM patients, VISTAQ was compared with conventional methods (mean+2SD, +5SD, +6SD, FWHM, visual thresholding). Prognostic performance was evaluated in 250 HCM patients over a median 5-year follow-up. Results VISTAQ demonstrated excellent intra- and inter-observer reproducibility (ICC up to 0.98 and 0.97, respectively), consistent across disease subtypes. Compared with conventional techniques, VISTAQ showed similar ICC to FWHM but significantly lower net and absolute inter-observer differences (median absolute difference 1.3%). Mean+2SD markedly overestimated LGE, whereas mean+6SD slightly underestimated LGE compared with VISTAQ, mean+5SD, FWHM, and visual thresholding. Analysis time was substantially shorter with VISTAQ (median 105 vs. 375 seconds, p<0.0001). During follow-up, 21 hard cardiac events occurred in HCM population. An LGE threshold >10% predicted events with higher accuracy using VISTAQ (AUC 0.90; sensitivity 85%; specificity 94%) compared with mean+6SD (AUC 0.75; sensitivity 57%; specificity 93%). Conclusions VISTAQ provides highly reproducible, time-efficient LGE quantification without dedicated software and demonstrates non-inferior prognostic discrimination in HCM compared with conventional threshold-based techniques.
Reference Key
openalex_W7154497520 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Imaging Methods and Practice
Year 2026
DOI
10.1093/ehjimp/qyag148
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.