Challenging the Limits of Mitral-TEER: A PASCAL Case in the Anatomical ‘Red Zone’: a case report

Clicks: 13
ID: 326828
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #303 of 408 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 408 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Transcatheter edge-to-edge repair (TEER) has emerged as an effective therapeutic option for patients with severe mitral regurgitation (MR) deemed high risk for surgery. Two devices are currently available in Europe, MitraClip (Abbott Vascular, Santa Clara, CA, USA) and PASCAL (Edwards Lifesciences, Irvine, CA, USA). The PASCAL system provides unique features, such as a central spacer and nitinol flexibility, that may expand eligibility in anatomically and clinically challenging cases. Case presentation We present the case of a 78-year-old female with ischemic cardiomyopathy and advanced heart failure (HF) (ejection fraction (EF) of 25%), severe secondary MR (SMR), chronic kidney disease and recurrent pulmonary edemas with hospitalizations with an STS score of 26.8%). Thus, transcatheter TEER was deemed the best option. The baseline mitral valve area (MVA) and mean gradient were 2.7cm2 and 2.4mmHg. Therefore, TEER with the PASCAL P10 device was selected as the most optimal device. A single device was implanted at the A2-P2 scallops, resulting in significant MR reduction and an acceptable final mean gradient of 4.5 mmHg. The patient was discharged clinically improved and without any hospitalizations for heart failure in 1-year follow up period. Discussion This case illustrates the feasibility of TEER with PASCAL in a frail, high-risk patient with severe SMR and borderline anatomy. The spacer technology and leaflet-friendly design allowed safe and effective MR reduction while maintaining acceptable gradients. This case highlights the importance of individualized heart team decision-making, the potential advantages of the PASCAL device in anatomically challenging scenarios and increased operator experience.
Reference Key
openalex_W7204489756 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag630
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.