A Novel WST-8-Based Colorimetric Method for Sensitive and Interference-Free Determination of Glutathione Peroxidase Activity

Clicks: 19
ID: 326771
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #12 of 33 articles by views in Biology Methods and Protocols

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Glutathione peroxidase (GPx) is a major antioxidant enzyme that protects cells from oxidative damage, and accurate quantification of GPx is important for biochemical, clinical, and diagnostic research. Current colorimetric and spectrophotometric GPx assays, however, are often limited by low sensitivity, unstable reagents, or interference from biological matrix components. We developed a colorimetric GPx assay based on the tetrazolium salt WST-8. GPx reduces peroxide substrates (ROOH) to water or the corresponding alcohols using reduced glutathione (GSH) as an electron donor, generating oxidized glutathione (GSSG); glutathione reductase then regenerates GSH from GSSG at the expense of NADPH. Unreacted NADPH reduces WST-8 to a stable, water-soluble formazan dye measured at 460 nm, so GPx activity can be calculated indirectly from the extent of NADPH consumption. Assay performance was compared with established DTNB- and UV-based GPx methods. The WST-8-based assay showed high sensitivity, a wide linear range, good reagent stability, and strong resistance to interference from sugars, amino acids, and proteins. Activity values obtained with the new method correlated closely with those from the conventional DTNB assay, confirming its accuracy. The WST-8-GPx assay offers improved sensitivity and interference resistance while remaining operationally simple and compatible with routine microplate instrumentation, making it a practical option for both clinical diagnostics and oxidative-stress research.
Reference Key
openalex_W7204471097 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Biology Methods and Protocols
Year 2026
DOI
10.1093/biomethods/bpag049
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.