Preliminary results of a single, easy-to-use device for multimodal detection of intervals associated with heart failure decompensation

Clicks: 4
ID: 325458
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #53 of 55 articles by views in European Heart Journal - Digital Health

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Aims The use of cardiac signal-recording tools to monitor prognostic and diagnostic parameters in heart failure is an emerging field, constrained by usability and a low signal-to-noise environment. We evaluated a compact, user-friendly prototype for simultaneous acquisition of PCG, PPG, ECG and subsequent processing, to determine this strategy’s usefulness in identifying parameters related to HF decompensation Methods and results We conducted a single-centre prospective study of 41 hospitalised patients; 36 included in the analysis. Autonomous recordings of phonocardiography, electrocardiography, and pulse-wave photoplethysmography were obtained. Signal processing employed a new supervised iterative filtering pipeline based on detection of coupled energy peaks, together with an independent analysis of the pulse-wave plethysmogram, enabling extraction of clinically relevant intervals even when one modality was of insufficient quality. In the cohort admitted with decompensated heart failure, measures at discharge showed shortening of electromechanical coupling time (0.148 ± 0.051 v. 0.108 ± 0.039 s; p < 0.001), isovolumetric contraction time (0.152 ± 0.098 v. 0.071 ± 0.023 s; p < 0.001) and ejection period (0.257 ± 0.078 v. 0.344 ± 0.082 s; p < 0.0001) compared with admission. These findings were corroborated against the cardiology inpatient cohort without clinical congestion and contextualised using a publicly available cohort of 338 healthy individuals. Conclusions This study presents initial evidence that a compact, easy-to-use device permits autonomous acquisition of diagnostic cardiac signals by non-expert users and that the proposed processing strategy reliably detects clinically relevant intervals in low-SNR recordings, supporting its potential utility for monitoring patients with heart failure.
Reference Key
openalex_W7203821326 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors David Sánchez-Ortiz, Mercedes Rivas‐Lasarte, Alejandro Nistal-Juarez, Luis Blanco-Tapia, Miguel Fribourg, Manuel Gómez-Bueno, Francisco José Hernández-Pérez, Cristina Mitroi, Alba Martin-Centellas, Ramón Garrido González, Martín Santos-González, Javier Segovia-Cubero
Journal European Heart Journal - Digital Health
Year 2026
DOI
10.1093/ehjdh/ztag135
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.