Artificial intelligence-based multimodal integration of ultrasound and digital breast tomosynthesis for breast-level risk classification
Clicks: 4
ID: 325437
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
0.9
/100
4 views
3 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #9 of 9 articles by views in precision clinical medicine
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract Background Breast cancer imaging frequently combines ultrasonography (US), digital mammography (DM) and digital breast tomosynthesis (DBT), yet integrating complementary findings remains labor-intensive. Methods We developed a parallel-branch deep learning framework for breast-level risk classification from paired US, DM and DBT examinations. The models were trained on 2,187 breasts and evaluated in an internal validation cohort of 632 breasts and an independent pathology-confirmed cohort of 500 breasts. Six single- and dual-modality models were compared. Results In the internal validation cohort, US–DBT achieved the highest observed AUC of 0.944 (95% CI, 0.926–0.963), exceeding US–DM and DM–DBT but not US; its sensitivity was 0.860 (95% CI, 0.805–0.904) and specificity was 0.904 (95% CI, 0.871–0.930). In the pathology-confirmed cohort, US–DBT achieved an AUC of 0.934 (95% CI, 0.913–0.955), exceeding US and DM–DBT but not US–DM. Its specificity was higher than that of all three models (0.955; 95% CI, 0.927–0.975; all adjusted P < 0.001), with a PPV of 0.958 (95% CI, 0.931–0.977) and sensitivity of 0.850 (95% CI, 0.807–0.887), which did not differ significantly from any of the three models. Performance remained favorable in dense breasts, lesions <2 cm and lower-suspicion BI-RADS strata. Conclusions These findings identify improved specificity as the principal added value of US–DBT and support its potential use as an adjunctive breast-level tool for refining positive imaging findings and prioritizing further diagnostic evaluation. Prospective validation in representative screening populations is required.
| Reference Key |
openalex_W7203783784
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Yujie Tan, Zhenjun Huang, Junwei Li, Ying Zhong, Qinyue Yao, Rui Chen, Yunfang Yu, Yaping Yang, Herui Yao |
| Journal | precision clinical medicine |
| Year | 2026 |
| DOI |
10.1093/pcmedi/pbag023
|
| URL | |
| Keywords | Keywords not found |
Citations