Artificial Intelligence-Enabled Electrocardiography for Detection of Left Ventricular Diastolic Dysfunction: A Systematic Review and Meta-Analysis

Clicks: 1
ID: 325268
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #52 of 55 articles by views in European Heart Journal - Digital Health

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Left ventricular diastolic dysfunction (LVDD) is an early precursor to heart failure with preserved ejection fraction (HFpEF) and it is currently diagnosed using echocardiography, a resource-intensive and operator-dependent modality that limits large scale screening. The 12-lead electrocardiogram (ECG) is widely available but lacks sufficient diagnostic accuracy for LVDD. Artificial intelligence (AI)-enhanced ECG analysis has emerged as a potential scalable alternative, although its overall diagnostic performance remains uncertain. Objectives To evaluate the diagnostic accuracy of AI-based algorithms for detecting LVDD in a systematic review and meta-analysis. Methods We systematically searched eight major databases through August 2025, complemented by forward and backward citation chasing. Studies reporting sensitivity and specificity of AI-ECG models, using echocardiography as the reference standard, were included. Pooled sensitivity, specificity, and area under the summary receiver operating characteristic curve (AUC) were estimated using a bivariate random-effects model. Results Five studies including 105,554 participants were analyzed. AI-ECG demonstrated a pooled sensitivity of 0.82 (95% CI: 0.81–0.83) and specificity of 0.77 (95% CI: 0.70–0.82), with an AUC of 0.85 (95% CI: 0.81–0.87). Substantial heterogeneity was observed (I2 = 98.5% for sensitivity and 99.8% for specificity), although results were robust in sensitivity analyses. Predictive values were prevalence-dependent. Negative predictive value was 98.8% at 5% prevalence and 93.7% at 22.2%, but declined to 81.1% at 50% prevalence and 64.7% at 70%. Conclusion AI-enhanced electrocardiography demonstrated good diagnostic performance for detecting LVDD and may support future rule-out or risk-enrichment strategies in selected populations. However, current evidence remains insufficient to support routine clinical implementation.
Reference Key
openalex_W7203698423 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Edjimbi Johann, Nisarg Shah, L. Donisi, Aryan Gajjar, Claudia See, Alyssa Grimshaw, Hassim Bachir Diop, Antonio Luiz P Ribeiro, Éloi Marijon, Gari Clifford, Bamba Gaye
Journal European Heart Journal - Digital Health
Year 2026
DOI
10.1093/ehjdh/ztag130
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.