Pulsed field ablation for paroxysmal atrial fibrillation and atrial flutter in a patient with dextrocardia and prior secundum atrial septal defect repair: a case report

Clicks: 8
ID: 324687
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #165 of 294 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 294 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Pulsed field ablation (PFA) is a novel non-thermal ablation modality that has demonstrated efficacy and safety in the treatment of common arrhythmias such as atrial fibrillation (AF) and atrial flutter (AFL). However, evidence regarding its use in patients with dextrocardia remains scarce. Case summary A 63-year-old woman with dextrocardia and situs inversus totalis, and with prior surgical atrial septal defect (ASD) repair, presented with heart palpitations that did not respond to antiarrhythmic drugs. Ambulatory and Holter monitoring documented short episodes of AF and AFL. Computed tomography (CT) of the heart and its structures before the procedure enabled anatomical orientation and planning of the procedure. Catheter ablation was performed using a Pentaspline PFA system (FARAPULSE, Boston Scientific) under fluoroscopic guidance without electroanatomical mapping. Pulmonary vein isolation, along with ablation of the left atrial roof, posterior wall of the left atrium, and cavotricuspid isthmus, was successfully achieved. The procedure was successful, and no recurrence of arrhythmia was observed on 6-month Holter monitoring. Discussion This case demonstrates that combined PFA for AF and AFL is feasible in patients with complex congenital anatomy, including dextrocardia following ASD repair. Mirror-image cardiac anatomy presents unique challenges for catheter navigation and anatomical orientation. Pre-procedural cardiac CT was essential for procedural planning and accurate spatial orientation, facilitating successful PFA in this anatomically complex setting.
Reference Key
openalex_W7202196534 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Assel Chinybayeva, Moldir Yerikkyzy, Zhanasyl Suleymen, Elmira Yessimbekova, Ayan Abdrakhmanov
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag599
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.