Real-life clinical validation of AI-assisted echocardiography for aortic root and LVOT measurements against human readers and cardiac magnetic resonance

Clicks: 1
ID: 324276
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #53 of 55 articles by views in European Heart Journal - Digital Health

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Aims AI algorithms may improve echocardiographic measurement standardization, but direct validation against cardiovascular magnetic resonance (CMR) remains limited. This study aimed to evaluate the agreement between AI-assisted transthoracic echocardiography (TTE), expert manual TTE, and CMR as a gold standard for aortic root and left ventricular outflow tract (LVOT) diameters. Methods and results Out of 183 patients with analyzable TTE and CMR recordings performed within seven days, 169 had complete measurements of LVOT, sinotubular junction (SoV) and sinus of Valsalva (STJ) by AI and were included in the primary analysis. Automated AI measurements were obtained using the US2.AI platform and compared with those of expert echocardiographers and CMR. Agreement was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Agreement between Expert 1 and CMR, and Expert 2 and CMR, yielded ICCs: 0.63 (95% CI: 0.50–0.73) and 0.51 (95% CI: 0.36–0.65) for LVOT, 0.71 (95% CI: 0.63–0.78) and 0.82 (95% CI: 0.73–0.87) for STJ, and 0.85 (95% CI: 0.79–0.89) to 0.85 (95% CI: 0.78–0.89) for SoV, respectively. AI-derived measurements demonstrated comparable agreement with CMR: ICC 0.70 (95% CI: 0.61–0.77) for LVOT, 0.77 (95% 0.70–0.83) for STJ, and 0.77 (95% 0.70–0.83) for SoV. Clinically significant differences (≥2 mm for LVOT and ≥4 mm for STJ and SoV) between AI vs CMR measurements were observed in 36.7% of LVOT, 20% of STJ, and 11.8% of SoV measurements. Conclusion AI-assisted echocardiography showed comparable agreement for aortic root and LVOT measurements, but physician oversight remains necessary.
Reference Key
openalex_W7196932513 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Patrycja Mołek-Dziadosz, Oleksandra Bondarchuk, Aleksandra Woźniak, Maria Królikowska, Agnieszka Mirek, Anna Furman-Niedziejko, Karol Mazur, Elżbieta Ostrowska-Kaim, Karolina Golińska‐Grzybała, Aleksander Siniarski, Joanna Szachowicz-Jaworska, Tomasz Miszalski-Jamka, Radosław Rychlak, Marc R. Dweck, Jadwiga Nessler, Andrzej Gackowski
Journal European Heart Journal - Digital Health
Year 2026
DOI
10.1093/ehjdh/ztag126
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.