Accuracy of Artificial Intelligence based chatbots in reporting jaw lesions from multimodal radiographic images: A cross-sectional study

Clicks: 4
ID: 323556
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #34 of 46 articles by views in dentomaxillofacial radiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
OBJECTIVES: The current study aimed to quantify the diagnostic accuracy of commonly utilized chatbots including Gemini, Copilot, Claude, and specialized architectures like Manus in the detection and differential diagnosis of various jaw lesions, while concurrently evaluating the clinical safety and fidelity of the information they provide. MATERIALS AND METHODS: Cone beam computed tomography (CBCT) dataset from 97 patients presented with jaw lesions were collected and anonymized. Panoramic 2D views were reconstructed from Digital Imaging and Communication in Medicine (DICOM) of all cases using Bluesky Plan software and provided to 4 chatbots (Gemini 2.5 Pro, Copilot, Claude and Manus). Moreover, the DICOM data was provided to Manus followed by prompting. The reports generated were evaluated for accuracy, relevance and feasibility. RESULTS: Statistically significant differences were detected between the chatbots in all measured parameters. In all evaluated parameters Manus CBCT showed the most accurate results (95% of lesions were detected and correctly diagnosed,). Gemini 2.5 pro ranked second where 80% of lesions were detected and 56% were correctly diagnosed. Manus Pan showed less accurate results. The least accurate results were detected in Copilot and Claude. CONCLUSION: Significant discrepancies exist among artificial intelligence (AI) chatbots regarding their diagnostic accuracy in reporting jaw lesions. Notably, the integration of raw 3-dimensional CBCT data substantially optimizes chatbot performance in lesion detection and diagnosis, as demonstrated by Manus architecture.
Reference Key
openalex_W7172392255 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Noha M. Elkersh, Aly Mohamed Atteya, Ahmed Abdelghany Shararah
Journal dentomaxillofacial radiology
Year 2026
DOI
10.1093/dmfr/twag057
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.