Clinical Applications of Impella 5.5 For Acute Severe Bioprosthetic Aortic Regurgitation: A Bridge to Destination Therapy Report – Case Series and Review
Clicks: 5
ID: 323544
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
1.2
/100
5 views
4 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #44 of 261 articles by views in European Heart Journal - Case Reports
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 261 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract Background Acute severe bioprosthetic aortic regurgitation complicated by cardiogenic shock represents a high-risk clinical scenario requiring urgent intervention. Conventional medical therapy is often insufficient, and options for mechanical circulatory support remain limited because severe aortic regurgitation is traditionally considered a relative contraindication to transvalvular support devices. Case Summary We describe two cases of acute severe bioprosthetic aortic regurgitation presenting with cardiogenic shock in which Impella 5.5 was utilized as temporary mechanical circulatory support to stabilize patients and facilitate definitive treatment. In the first case, Impella 5.5 support enabled successful bridge to valve-in-valve transcatheter aortic valve replacement. In the second case, Impella 5.5 was used as a bridge to redo surgical aortic valve replacement. In both cases, hemodynamic stabilization and end-organ recovery allowed progression to destination therapy. Discussion These cases demonstrate that, in carefully selected patients with acute severe bioprosthetic aortic regurgitation and cardiogenic shock, Impella 5.5 may serve as a feasible bridge to definitive valve intervention. Although severe aortic regurgitation has traditionally limited the use of transvalvular mechanical support, these experiences suggest a potential role for Impella 5.5 in individualized management strategies. Further studies are needed to better define patient selection, safety, and outcomes.
| Reference Key |
openalex_W7172270886
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ahmed Elshafie, Hussam Al Hennawi, Ahmad Abulshamat, Shaurya Srivastava, RAJIT PAHWA, Appa Bandi, Hisham Qandeel, Mohammed Qintar |
| Journal | European Heart Journal - Case Reports |
| Year | 2026 |
| DOI |
10.1093/ehjcr/ytag573
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.