First Use of Pulsed Field Ablation in a Patient With a Deep Brain Stimulator: A Case Report
Clicks: 1
ID: 323001
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #208 of 247 articles by views in European Heart Journal - Case Reports
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 247 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract Background Pulmonary vein isolation for atrial fibrillation (AF) in patients with implanted neurostimulation devices is challenging, as established energy sources such as radiofrequency (RF) ablation are generally not recommended in these patients due to the risk of device interference. Pulsed field ablation (PFA) for AF offers relative myocardial selectivity and a potentially improved safety profile. However, data on its use in patients with implanted neurostimulation devices are lacking. Case summary A 66-year-old woman with paroxysmal AF was referred to our center for catheter ablation. Years earlier, a deep brain stimulator (DBS) had been implanted to control severe fasciculations. As RF ablation is not recommended in such patients and given the patient’s multiple comorbidities, a single-shot ablation strategy was chosen. After selective pulmonary vein angiography revealed a large left common pulmonary vein (LCPV), PFA using a pentaspline catheter was selected, as this approach allows effective treatment of a LCPV with short procedure times and a favorable safety profile. The DBS was deactivated prior to the procedure and ablation was performed without complications. After the procedure, the DBS was reactivated and showed no evidence of device malfunction. Discussion This is the first reported case that demonstrates the feasibility of PFA in a patient with an implanted DBS. Temporary deactivation of the neurostimulation device and careful multidisciplinary planning allowed successful ablation without device dysfunction or interference. These findings suggest that, with appropriate precautions, PFA may represent a viable ablation strategy in selected patients with implanted neurostimulation systems.
| Reference Key |
openalex_W7171816853
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Julia Alexandra Marx, David Schaack, K. R. Julian Chun, Boris Schmidt, Lukas Urbanek |
| Journal | European Heart Journal - Case Reports |
| Year | 2026 |
| DOI |
10.1093/ehjcr/ytag560
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.