Ultrasound-Based Estimation of Periodontal Probing Depth Using Category-Specific Supracrestal Tissue Attachment Calibration

Clicks: 5
ID: 322276
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #11 of 46 articles by views in dentomaxillofacial radiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
OBJECTIVE: To determine category-specific supracrestal tissue attachment (STA) dimensions and apply these values to calibrate high-frequency ultrasound-derived measurements to match clinical probing depth (PD), and to examine the reliability of ultrasound landmark annotation in healthy and diseased cohorts. METHODS: Intraoral high-frequency ultrasound (40 MHz) imaging was performed to acquire images from 34 subjects (20 healthy and 14 with stage II-IV periodontitis). Four trained raters annotated 955 teeth for the gingival margin (GM), cemento-enamel junction (CEJ), and alveolar bone crest (ABC). The image-based gingival height (iGH) was defined as the distance from the gingival margin to the average bone crest. Ultrasound assessment is in terms of distances to the bone crest, whereas probing depth is measured to the supracrestal tissue attachment. Ultrasound measurements were calibrated using category-specific STA values to estimate probing depth. Method agreement between iPD and clinical PD was evaluated via Bland-Altman analysis using a ±1 mm clinical acceptance limit. This prospective calibration-validation study (34 subjects; 955 annotated tooth-surface observations) compared high-frequency ultrasound-derived measurements with conventional clinical periodontal probing depth measurements. The dataset was partitioned into a calibration set (721 observations, 27 subjects) and an independent validation set (234 observations, 7 subjects). RESULTS: Inter- and intra-rater reliability was high, with correlation coefficients ranging from 0.894 to 0.998. Calibrated STA values ranged from 1.349 mm for molar-buccal to 2.970 mm for anterior-buccal teeth, yielding an overall mean of 2.162±0.549 mm that falls within established histological reference ranges. Validation analysis (n = 234 teeth) demonstrated 80.8% agreement between iPD and clinical PD within ±1 mm, with a mean bias of -0.137 mm and limits of agreement of -1.718 to + 1.443 mm. CONCLUSIONS: Category-specific STA-calibrated high-frequency intraoral ultrasound enables clinically acceptable PD estimation across tooth types and surfaces without ionizing radiation or probe-induced discomfort. The observed level of agreement lies within the reported inter-examiner variability of conventional periodontal probing. ADVANCES IN KNOWLEDGE: This study represents the initial comprehensive characterization of supracrestal tissue attachment for all tooth types and surfaces by means of high-frequency ultrasound, which illustrates that calibration for each of these tooth type groups is essential for accurate estimation of probing depth. This approach may provide a non-invasive adjunct to periodontal probing assessment.
Reference Key
openalex_W7170472855 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Mohammadreza Amjadian, Gulcan Gok, Nicholas Choi, Suhel Khan, Mirali Pandya, Jesse V. Jokerst, Casey Chen
Journal dentomaxillofacial radiology
Year 2026
DOI
10.1093/dmfr/twag050
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.