A Case Report of an S-ICD–Recorded Asystole due to SMART Pass Deactivation in a Patient With Non-Obstructive Hypertrophic Cardiomyopathy

Clicks: 3
ID: 321844
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #187 of 261 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 261 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background The SMART Pass (SP) algorithm of the subcutaneous implantable cardioverter-defibrillator (S-ICD; Boston Scientific Emblem) uses a high pass filter to reduce inappropriate shocks due to signal oversensing. In cases of small to none R-wave amplitude the SP algorithm is automatically deactivated and an electrocardiogram (ECG) is recorded. Case Summary A 63-year-old patient with hypertrophic cardiomyopathy (HCM) without left ventricular outflow tract obstruction underwent implantation of an S-ICD. When the patient reported syncope months later device interrogation revealed SP deactivation due to a 22-second asystole, consistent with the timing of the syncope. Prior to the event, there was no indication of future pacing requirement. The patient had a stable two-vessel coronary artery disease as well as unaltered echocardiographic findings including preserved left ventricular ejection fraction. The S-ICD was replaced by a transvenous dual-chamber implantable cardioverter-defibrillator. Discussion Although bradycardia detection is not available in the S-ICD system, in our case it was enabled due to ECG recording performed during SP deactivation, which outlines the importance of careful investigation. Since bradyarrhythmia in HCM is considered rare it has been studied far less extensively than atrial and ventricular tachyarrhythmia. There is substantial evidence that myocardial fibrosis is a significant predictor of ventricular tachycardia and sudden cardiac death. However more extended research is required to further investigate the association between myocardial fibrosis and bradyarrhythmia in patients with HCM as well as to evaluate the potential of Magnetic Resonance Imaging-based screening to identify patients at risk requiring future pacing.
Reference Key
openalex_W7170051824 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Marie Lajos, Wim Rother, Thomas Hucko, Kristof Graf, Sebastian Spencker
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag543
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.