Automated quality indicators for echocardiographic recordings and measurements: Consequences for left ventricular global longitudinal strain

Clicks: 1
ID: 321701
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #41 of 47 articles by views in European Heart Journal - Imaging Methods and Practice

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Aims Global longitudinal strain (GLS) is a sensitive measure of left ventricular (LV) function, though hampered by a significant variability. Data on how echocardiographic recordings and measurements influence GLS and its variability are scarce. We aimed to study the consequences of variability in echocardiographic recordings and measurement procedures for GLS in a normal population. Methods and results Healthy participants (n = 1,412) from the Trøndelag Health Study were examined by echocardiography according to current recommendations. Four experienced operators read and re-read all GLS recordings (2,824 measurement procedures). Characteristics of echocardiographic recordings and measurement procedures were extracted by deep learning (DL) and software metadata. LV apical endocardium was positioned mean 26 mm from top of the sector and 6 mm to the left of the central axis. Mean LV foreshortening ranged 1.2-2.1 mm in apical views and the recordings were well standardized with the preferred cut-planes for tilt and rotation. GLS (in percentage points) was lower with reduced image quality (0.8), longer LVs (0.2 per cm), wider regions of interest (0.8 per mm) during the measurement procedure, and longer distance (0.07 per mm) from the transducer to the LV apex, respectively. Moreover, GLS was 0.7 percentage points higher per mm apical foreshortening, and also higher when a more refined ROI initialization was used. Conclusion Using novel DL methodology and available metadata, we found that indicators of image standardization and measurement procedures influenced GLS. Implementing such quality indicators during recording and measurement procedures may improve the efficacy of echocardiography and ease the interpretation of differences between studies.
Reference Key
openalex_W7169787765 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Even Olav Jakobsen, Andreas Østvik, David Pasdeloup, Erik Smistad, John Nyberg, Stian Stølen, Lasse Løvstakken, Espen Holte, Bjørnar Grenne, Håvard Dalen
Journal European Heart Journal - Imaging Methods and Practice
Year 2026
DOI
10.1093/ehjimp/qyag124
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.