Entrapment of a J-tip guidewire within the pulmonary vein during FARAPULSETM pulsed field ablation. A case report
Clicks: 11
ID: 320763
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
3.0
/100
11 views
6 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #3 of 283 articles by views in European Heart Journal - Case Reports
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 283 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract Background Pulsed field ablation (PFA) is a rapidly adopted technology for atrial fibrillation (AF) ablation and is associated with a favorable safety profile and a low risk of complications. However, mechanical complications have rarely been reported. Case summary A 37-year-old Asian male with paroxysmal AF underwent PFA using the FARAPULSETM system. Following successful ablation of the left superior pulmonary vein (PV), the J-tip guidewire advanced into the left inferior PV and became completely entrapped. Venography demonstrated that, although the guidewire tip remained intravascular, a proximal segment appeared to course along the vessel wall, suggesting passage through an intraluminal structure. Multiple attempts at withdrawal using push-pull maneuvers were unsuccessful. Repositioning with a radiofrequency ablation catheter also failed to release the entrapment. Given the risk of vessel rupture and major hemorrhage, the procedure was converted to general anesthesia in a hybrid operating room with surgical standby. Bridge occlusion balloon-assisted extraction successfully released the entrapped guidewire without vascular injury. The retrieved guidewire had adherent fibrous white tissue, suggesting entrapment by a membranous pulmonary venous structure. Discussion Balloon-assisted endovascular retrieval may represent a safe and less invasive alternative to surgical intervention for managing such entrapments. Operators should be aware of this rare but potentially hazardous complication.
| Reference Key |
openalex_W7168097484
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ken Watanabe, Takanori Arimoto, Yuta Kobayashi, Naoaki Hashimoto, Masafumi Watanabe |
| Journal | European Heart Journal - Case Reports |
| Year | 2026 |
| DOI |
10.1093/ehjcr/ytag503
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.