Automated Whole-Heart Volumetrics and Haemodynamics from 4D Flow CMR Magnitude Images: Development and Validation of a Deep Learning Model

Clicks: 1
ID: 320330
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #37 of 47 articles by views in European Heart Journal - Imaging Methods and Practice

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background 4D flow cardiovascular magnetic resonance (CMR) offers a comprehensive haemodynamic assessment but is often limited by long acquisition times and complex post-processing. The magnitude images derived from 4D flow sequences contain time-resolved 3D anatomical information. We aimed to validate the anatomical accuracy of these images against standard cine imaging and develop an artificial intelligence (AI) model for automated segmentation to facilitate analysis. Methods 40 patients prospectively identified from the PREFER-CMR registry underwent CMR, including standard cine stacks and 4D flow. The study consisted of two stages. In Stage 1, manual segmentation of the cardiac chambers and great vessels was performed on 4D flow magnitude images. These were validated against standard cine volumetrics (LV/RV) and normative reference values (LA/RA). In Stage 2, a fully automated deep learning algorithm was trained and validated. Advanced haemodynamic metrics were derived using both manual and AI segmentations to assess agreement. Results The study cohort (n=40) had a mean age of 69.0 ± 17.2 years, and 60.0% were male. In Stage 1, 4D flow magnitude analysis demonstrated excellent correlations with cine measurements for LV end-diastolic volume (LVEDV) (ρ=0.98, ICC=0.99) and RV end-diastolic volume (RVEDV) (ρ=0.97, ICC=0.98). In Stage 2, the AI model achieved excellent segmentation performance (mean Dice similarity coefficient 0.88). Comparisons of haemodynamic metrics derived from AI versus manual contours showed strong agreement (r ≥ 0.88 for all peak metrics). Conclusion 4D flow magnitude imaging provides accurate volumetrics. Deep learning automation of this process is feasible, allowing for rapid, comprehensive assessment of cardiac structure, function, and advanced energetics.
Reference Key
openalex_W7167818696 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Alexander Gall, Ciaran Grafton‐Clarke, Rui Li, Zia Mehmood, Bahman Kasmai, Marina Hughes, Peter Swoboda, Rob J. van der Geest, Vassilios S. Vassiliou, Gareth Matthews, Pankaj Garg
Journal European Heart Journal - Imaging Methods and Practice
Year 2026
DOI
10.1093/ehjimp/qyag125
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.