The Polystyrene Beads Sign: A Simple MRI Marker for the Preoperative Diagnosis of Papillary Hypothalamic Craniopharyngiomas
Clicks: 1
ID: 318331
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #55 of 91 articles by views in european journal of endocrinology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
OBJECTIVE: Craniopharyngiomas are classified as adamantinomatous or papillary subtypes. Papillary craniopharyngiomas harbor BRAF V600E mutations and demonstrate high response rates to BRAF/MEK inhibition. Craniopharyngiomas involving the hypothalamus are common and carry high surgical morbidity, including endocrine, metabolic, and neurocognitive complications. Therefore, reliable preoperative identification of papillary hypothalamic tumors could support consideration of biopsy followed by targeted therapy, potentially avoiding high-risk surgery. DESIGN: This study is a single-center retrospective study. METHODS: We retrospectively analyzed 61 adult patients with hypothalamic craniopharyngiomas. We defined a novel MRI biomarker, the polystyrene beads sign, as an agglomerate of small, rounded, contrast-enhancing nodules on high-resolution T1-weighted post-contrast MRI. Six independent clinicians, blinded to histopathology, evaluated the presence of the sign. Diagnostic performance (sensitivity, specificity, accuracy) and intra- and interrater reliability were assessed. RESULTS: The polystyrene beads sign identified papillary tumors with 92% sensitivity, 98% specificity, and 96% overall diagnostic accuracy. Intrarater reliability across two separate readings was high, and interrater reliability among all six clinicians was excellent. After a brief calibration session, the sign was consistently recognizable and distinguishable from enhancement patterns observed in adamantinomatous tumors. CONCLUSIONS: The polystyrene beads sign is a simple and reproducible preoperative MRI marker that may help identify papillary hypothalamic craniopharyngiomas. These findings support further evaluation in multicenter studies before clinical implementation. Its recognition may contribute to imaging-based diagnostic strategies, including selection of patients for confirmatory biopsy, molecular testing, and subsequent targeted therapy in appropriate cases.
| Reference Key |
openalex_W7165539917
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Bertrand Baussart, Arianna Fava, Maxime Barat, Thibault Passeri, Anthony Dohan, Luca Ferlendis, Anne Jouinot, Jennifer Arrondeau, Julian Jacob, Valentin Calugaru, Mirella Hage, Philippe Touraine, Camille Vatier, Marie Laloi, Carine Courtillot, Jérôme Bertherat, Chiara Villa, Guillaume Assié, Sébastien Froelich |
| Journal | european journal of endocrinology |
| Year | 2026 |
| DOI |
10.1093/ejendo/lvag108
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.