Augmentation Mastopexy With Polyurethane-Coated Implants in the Prepectoral Plane: A 24-Month Follow-Up Study
Clicks: 3
ID: 318278
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
0.6
/100
3 views
2 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #61 of 81 articles by views in Aesthetic Surgery Journal Open Forum
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract Background Augmentation mastopexy aims to restore breast shape and volume in patients with ptosis. Polyurethane-coated implants may enhance implant stability in augmentation mastopexy through early tissue adhesion in the prepectoral plane; however, mid-term stability and clinical outcomes remain incompletely defined, prompting the need for the present study. Objectives To evaluate the long-term aesthetic stability, complication profile, and patient satisfaction associated with augmentation mastopexy using polyurethane-coated implants placed in the prepectoral plane, with or without selective fat grafting. Methods From January 2019 to December 2023, 169 patients (338 breasts) underwent augmentation mastopexy with polyurethane-coated implants placed in the prepectoral plane. The surgical protocol included mastopexy, implant placement, and selective fat grafting, when needed, to optimize breast contour in patients with asymmetries or minimal soft tissue coverage (e.g. pinch test <2cm). Patients were followed up at 1, 6, 12, 18 and 24 months postoperatively, with the primary endpoint being the nipple-to-jugular distance (NJD), used to assess breast stability. Patient satisfaction was assessed using a 5-point Likert scale at 12 months. Results The average preoperative NJD was 27.4 cm, and postoperatively, a significant reduction was observed at 1 month (21.5 cm), with minimal increase over time (22.3 cm at 24 months), indicating stable breast positioning. A single case of capsular contracture was managed with implant replacement. Patient satisfaction was high, with 78% rating their results as “very satisfied” (score 5). Conclusions Augmentation mastopexy with polyurethane-coated implants placed in the prepectoral plane provides stable, long-term breast positioning and high patient satisfaction. This technique offers a reliable alternative to traditional approaches, with minimal complications and sustained aesthetic results.
| Reference Key |
openalex_W7165642247
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | C Mele, Andrea Murante, Edoardo Auriemma, Giuseppe Esposito, Luigi Castiello, Vincenzo Rullo, Santolo D’Antonio |
| Journal | Aesthetic Surgery Journal Open Forum |
| Year | 2026 |
| DOI |
10.1093/asjof/ojag118
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.