Clinical Improvement of Functional Mitral and Tricuspid Regurgitation Following Transcatheter Aortic Valve Implantation with the NAVITOR VISION System: A Case Report

Clicks: 1
ID: 318237
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #204 of 248 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 248 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Concomitant mitral regurgitation (MR) and tricuspid regurgitation (TR) are frequently encountered in patients with severe aortic stenosis (AS) and are associated with adverse clinical outcomes after transcatheter aortic valve implantation (TAVI). However, the impact of transcatheter heart valve selection on postprocedural multivalvular hemodynamics remains incompletely understood. Case Summary An 87-year-old woman with symptomatic low-flow, low-gradient aortic stenosis (AS) complicated by moderate-to-severe mitral regurgitation (MR) and severe tricuspid regurgitation (TR) was admitted with refractory heart failure despite intensive medical therapy. Given her advanced age, frailty, and high surgical risk, transfemoral transcatheter aortic valve implantation (TAVI) was performed using a 23-mm Navitor™ Vision valve (Abbott Structural Heart, Santa Clara, CA, USA). Valve selection was guided by the presence of a small aortic annulus and the need to balance optimal haemodynamic performance with minimisation of potential mitral valve interaction. The procedure was successfully completed without significant residual transvalvular gradient or paravalvular leakage. Following TAVI, relief of afterload was achieved, leading to improvement in functional MR and TR, with discontinuation of inotropic support. Follow-up echocardiography demonstrated reduction in both MR and TR, accompanied by a decrease in right ventricular systolic pressure. Conclusion We report a case of symptomatic low-flow, low-gradient AS with concomitant MR and TR that was successfully treated with TAVI using a Navitor Vision valve. In patients with small annuli and complex multivalvular disease, careful transcatheter heart valve selection and procedural optimisation may facilitate favourable haemodynamic outcomes and reverse remodelling.
Reference Key
openalex_W7165520702 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Akira Otani, Joshi Tsutsumi, Tatsuki Doijiri, Minako Hayakawa, Mimiko Tabata
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag479
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.