A measurement comparability study to support instrument harmonization in the Canadian longitudinal study on aging
Clicks: 1
ID: 318192
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #293 of 305 articles by views in american journal of epidemiology
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 305 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Longitudinal studies are essential for understanding health trajectories, but necessary upgrades to measurement instruments over time may compromise data comparability. The Canadian Longitudinal Study on Aging conducted a measurement comparability study to quantify systematic differences between instruments and derive conversion equations to correct for any differences. Overall, 50 participants aged ≥ 45 years (52% females) underwent repeated assessments with old and new instruments including the blood pressure monitor, electrocardiogram (ECG), carotid ultrasound, spirometer, audiometer, tonometer, and dynamometer. Linear mixed-effects models were used to identify systematic differences. Cohen's d was used to assess standardized mean difference, Bland-Altman plots evaluated agreement between instruments, and repeatability was assessed within instruments. Mixed-effects models showed no clinically meaningful difference across instruments, except for systolic blood pressure (SBP), which was on average 5.19 mmHg (95% CI, 2.64, 7.74) higher using the new instrument. Cohen's d demonstrated moderate systematic differences for several measures. Repeatability estimates showed good-to-excellent reliability for most measures; however, certain ECG and tonometer parameters showed moderate or poor precision. The results support the utility of conversion equations to account for systematic differences between instruments. The difference in SBP warrants the implementation of a conversion equation, whereas it is unclear for measures with moderate differences.
| Reference Key |
openalex_W7165539363
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Talha Rafiq, Lauren E. Griffith, P L Raina, Christina Wolfson, Susan Kirkland, Cynthia Balion, Andrew P. Costa, Varun Chaudhary, MyLinh Duong, Danielle Glista, Philip Joseph, Maureen J. MacDonald, Jack Scott, David B. Hogan, Edwin van den Heuvel |
| Journal | american journal of epidemiology |
| Year | 2026 |
| DOI |
10.1093/aje/kwag137
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.