Stable Valve Function After Post-Transapical TAVR With Anchoring Strut Fracture: A 3-Year Multimodal Imaging Follow-up Case Report
Clicks: 6
ID: 318083
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
1.5
/100
6 views
2 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #10 of 261 articles by views in European Heart Journal - Case Reports
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 261 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract Background Transcatheter aortic valve replacement (TAVR) for native aortic regurgitation (AR) remains technically challenging due to the absence of annular calcification and difficulties in achieving stable anchoring. Mechanical complications such as anchoring strut fracture are rare but may have implications for long-term valve durability. Case summary A 64-year-old man with severe symptomatic native AR underwent transapical TAVR using a 29-mm self-expanding J-Valve system. Routine echocardiography and gated CT on postoperative day 7 identified an isolated fracture of the right coronary sinus anchoring strut without migration, leaflet dysfunction, or hemodynamic compromise. No balloon post-dilatation was performed. Serial multimodal imaging over nearly three years demonstrated persistent structural stability, preserved valve function, and marked left-ventricular reverse remodeling. Discussion This case provides long-term multimodal imaging follow-up of isolated anchoring strut fracture after TAVR for native AR. Early fracture detection and absence of calcification support a deployment-related stress mechanism rather than late cyclic fatigue. Although this favorable evolution suggests that isolated fracture does not necessarily result in immediate structural valve dysfunction, prognostic conclusions cannot be generalized. Careful, individualized imaging surveillance remains essential.
| Reference Key |
openalex_W7165443399
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Wei-tong Liu, Dacheng Li, Kai Zhang, Sumin Yang, Lei Jiang |
| Journal | European Heart Journal - Case Reports |
| Year | 2026 |
| DOI |
10.1093/ehjcr/ytag448
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments