Transcatheter edge-to-edge repair with DragonFlyTM system and “Stepless Self-locking” strategy in a patient with mixed mitral regurgitation: a case report

Clicks: 5
ID: 318081
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #45 of 261 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 261 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Transcatheter edge-to-edge repair (TEER) has emerged as an alternative treatment for severe mitral regurgitation (MR). However, complex anatomical features of mitral valve pose significant technical and procedural challenges for TEER. In patients whose effective regurgitation reduction requires multiple clips, a small valve area (MVA) limits TEER by increasing the risk of post-procedural elevated transvalvular gradients and iatrogenic stenosis. Case Summary A 90-year-old man presented with progressive tightness of breath that remained refractory to drug-based medical therapy. Echocardiography revealed severe mixed mitral regurgitation characterized by C1 segment prolapse and atrial functional mitral regurgitation with a small MVA of 4.09 cm2. Given his advanced age and prohibitive surgical risk [Society of Thoracic Surgeons (STS) score for repair: 10.49%], the multidisciplinary Heart Team elected to perform TEER using the DragonFlyTM system. The procedure was successfully performed under transoesophageal echocardiographic (TEE) guidance with the sequential implantation of two clips. The second clip utilized a “Stepless Self-locking” strategy to carefully balance the reduction of regurgitation against the transmitral pressure gradient elevation. Regurgitation was reduced from grade 4+ to 1+ with a final mean gradient of 4 mmHg and no evidence of significant mitral stenosis. The patient experienced a marked improvement in functional status during the follow-up period. Discussion This case highlights the importance of individualized anatomical assessment and tailored device selection in managing patients with MR and complex, challenging structure. Precise clip sizing and stepwise deployment strategies can successfully balance MR reduction while preserving MVA. Such tailored approaches are essential to prevent iatrogenic complications and optimize clinical outcomes in high-risk populations.
Reference Key
openalex_W7165442892 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Xinping Lin, Yuming Wang, Boren Tan, Jianan Wang, Xianbao Liu
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag435
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.