Transoral Neuromuscular Electrical Stimulation Therapy Adherence and Intensity Levels in Veterans with Mild OSA
Clicks: 1
ID: 317245
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #27 of 39 articles by views in SLEEP Advances
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract Study Objectives To describe the use of transoral neuromuscular stimulation therapy in Veterans with mild obstructive sleep apnea (OSA) by looking at session-level data for both adherence and stimulation intensity. Methods A retrospective review of session-level data of the 82 patients prescribed the eXciteOSA device at the VA San Diego Healthcare System (VASDHS) was analyzed. The device is prescribed for use over two phases: (1) Phase 1: one daily 20-minute session daily for 42 days, and (2) Phase 2: one daily 20-minute session on two days per week. Results Forty-one out of 76 patients (54%) completed Phase 1 (42 sessions) within the first 60 days of using eXciteOSA therapy. Three (4%) completed Phase 1 after the first 60 days, and 32 (42%) patients never completed Phase 1. Initial Phase 1 graduates had a cumulative usage of 866 minutes, while those that did not complete Phase 1 had 578 minutes. Average stimulation intensity levels in the initial Phase 1 graduates increased from week 1 to week 6 (from 3.2 to 11.2). Conclusions Based on the prescription-based adherence definition, adherence is modest but is contingent on how adherence is defined. Notably however, median positive airway pressure adherence is 40% for those with a recent prescription within our facility for comparison. Future research should focus on interventions to help improve both adherence and stimulation intensity levels of this novel daytime OSA therapy.
| Reference Key |
openalex_W7164672962
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Carl Stepnowsky, Tania Zamora, Yzabel Velazquez, Christopher N. Schmickl, Cesar Cervantes-Gameros, Robert L Owens, Brian S. Wojeck, Peter Colvonen, Brandon Nokes |
| Journal | SLEEP Advances |
| Year | 2026 |
| DOI |
10.1093/sleepadvances/zpag061
|
| URL | |
| Keywords | Keywords not found |
Citations