Cerebral air embolism after implantation of a leadless pacemaker via the right internal jugular vein: a case report

Clicks: 1
ID: 316461
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #186 of 251 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 251 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Leadless pacemaker (LP) implantation is associated with fewer device-related complications than conventional transvenous pacing systems. While traditionally performed via the femoral vein, the right internal jugular (RIJ) approach has recently emerged as an alternative strategy, potentially improving catheter control. However, safety data for this approach remain limited. Case summary A 77-year-old man with precapillary pulmonary hypertension, diabetes mellitus, and recurrent traumatic syncope underwent LP implantation via the RIJ vein following documentation of infra-Hissian conduction delay (HV interval 80 ms). The procedure was uneventful, with satisfactory electrical parameters. Immediately after repositioning the patient in a 30° head-up position, he developed acute neurological deterioration (Glasgow Coma Scale 6/15). Transthoracic echocardiography excluded pericardial effusion but revealed air bubbles in the right ventricle. Cerebral computed tomography demonstrated multiple air bubbles within the right intracerebral venous system, consistent with retrograde cerebral venous air embolism. Emergency management included Trendelenburg positioning, 100% oxygen administration, and hyperbaric oxygen therapy. Neurological status improved, although a persistent left-sided motor deficit remained. At 15-month follow-up, no further syncope occurred, and the LP functioned normally, but residual left limbs hypokinesia persisted. Discussion This case illustrates a rare but severe complication of RIJ LP implantation. Large-bore sheath use, low venous pressure in the jugular system, relative dehydration, severe pulmonary vascular disease, and early head-up positioning likely contributed to retrograde cerebral venous air migration. Strict preventive measures—including meticulous system flushing, adequate hydration, maintenance of slight Trendelenburg positioning, and post-procedural echocardiographic screening—may help mitigate this risk.
Reference Key
openalex_W7163991104 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Pierre Ollitrault, Mayane Al Khoury, Laure Champ‐Rigot, Jonaz Font, Arnaud Pellissier
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag446
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.