Early Performance of a Multifilament Resorbable Synthetic Mesh in Aesthetic Breast Surgery: A 206 Patient Experience

Clicks: 1
ID: 316387
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #65 of 81 articles by views in Aesthetic Surgery Journal Open Forum

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Increasing evidence supports the role of soft-tissue reinforcement in enhancing outcomes and longevity in breast surgery. Maintenance of lower pole shape, soft-tissue support and implant position often requires use of mesh in aesthetic procedures. The authors describe their experience utilizing a fully resorbable multifilament scaffold (TIGR® Matrix) as an alternative to biologic and synthetic meshes. Objectives To assess early safety and performance outcomes when TIGR Matrix is utilized in primary and revision cosmetic breast surgery. Methods We began routinely utilizing TIGR Matrix in aesthetic breast surgeries in 2023 and retrospectively reviewed all patients who underwent primary or revision elective cases with the mesh. Indication for use and examination of product performance was performed via a retrospective Results TIGR Matrix was used in two hundred six patients (407 breasts), mean age 42.6 years, with mean follow- up of 9.2 months. Mean BMI was 24.2 with 30 patients (14.6%) having a history of massive or major weight loss. One hundred fourteen cases (55.3%) were primary procedures, 92 (44.7%) were revisions. Mesh was placed in the subfascial position in 97 (47.1%) cases and submuscular in 109 (52.9%). Ten patients (4.9%) required post-operative intervention; 5 seromas in 4 patients (1.9%) required mesh removal and implant exchange and 6 patients required revision surgeries due to animation deformity (5) and implant displacement (1). Conclusions Use of TIGR Matrix demonstrated early safety and effectiveness, achieving consistent clinical outcomes in both primary and revision aesthetic breast surgeries.
Reference Key
openalex_W7163924379 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Renee Burke, Charalambos Rammos
Journal Aesthetic Surgery Journal Open Forum
Year 2026
DOI
10.1093/asjof/ojag109
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.