Liver fibrosis staging with combination of APRI and FIB-4 scoring systems in chronic hepatitis C as an alternative to transient elastography.

Clicks: 287
ID: 31604
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #3 of 3 articles by views in annals of gastroenterology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Liver disease severity must be determined before treatment of chronic hepatitis C (CHC). We evaluated the diagnostic performance of the APRI and FIB-4 scores compared to transient elastography liver stiffness (TE-LS) in detecting significant fibrosis (F3) or cirrhosis (F4).We retrospectively enrolled 575 patients with CHC who underwent TE-LS between May 2014 and September 2018: 365 (63.5%) male, mean age 51.54±12.4 years. APRI and FIB-4 scores were compared to TE-LS.One hundred patients (17.5%) had TE-LS values between 9 and 11.9 kPa, and were classified as F3, while 265 (46%) were classified as F4 (TE-LS ≥12 kPa). APRI and FIB-4 scores predicted F4 patients adequately using cutoff values of 0.65 (sensitivity 85.5%, specificity 77%) and 1.63 (sensitivity 91%, specificity 77%), respectively. Cutoff values of 0.64 for APRI and 1.46 for FIB-4 predicted F3/F4 patients (sensitivity 72% and 81.5%; specificity 83% and 79%, respectively). The use of these cutoff values with APRI and FIB-4 in combination adequately predicted patients with significant fibrosis or cirrhosis (positive predictive value 91.5%), while cutoff values of 0.3 and 0.98, respectively, predicted F1/F2 patients with specificity 94.5% and sensitivity 26.5%, suggesting that in 58.5% of patients TE-LS could possibly be avoided.The APRI/FIB-4 combination performed well in predicting significant fibrosis, while FIB-4 performed well in predicting cirrhosis. These noninvasive biochemical markers could be used as screening tools instead of LS measurement, which is not widely available. Further prospective validation studies are required to confirm this finding.
Reference Key
papadopoulosliverannals Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Papadopoulos, Nikolaos;Vasileiadi, Sofia;Papavdi, Maria;Sveroni, Eirini;Antonakaki, Pinelopi;Dellaporta, Erminia;Koutli, Evangelia;Michalea, Stavroula;Manolakopoulos, Spilios;Koskinas, John;Deutsch, Melanie;
Journal annals of gastroenterology
Year Year not found
DOI
10.20524/aog.2019.0406
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.