Artificial intelligence for reducing metal artifacts in dental CBCT images: a systematic review

Clicks: 1
ID: 315061
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #45 of 46 articles by views in dentomaxillofacial radiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Objectives The presence of metallic restorations introduces severe artifacts that compromise diagnostic accuracy of cone beam computed tomography (CBCT) images. This systematic review aims to evaluate the effectiveness of artificial intelligence (AI) techniques in reducing metal artifacts in dental CBCT images. Methods A comprehensive literature search was conducted across six databases up until April 2025, using keywords related to AI and CBCT artifact reduction. Studies were selected based on the eligibility criteria, focusing on AI models trained on human CBCT scans targeting dental regions. Data extraction and risk of bias assessment were performed independently by several reviewers accordingly. Risk of bias was independently assessed using the QUADAS-2 tool. Results Ten studies published between 2019 and 2025 met the eligibility criteria. The majority of included studies had a high risk of bias. The most employed deep learning architectures wereU-Net, GANs, and transformer-based models. Quantitative metrics like SSIM, PSNR, and RMSE demonstrated consistent improvements in image quality, while qualitative assessments confirmed superior artifact suppression and anatomical detail preservation compared to conventional methods. Transformer-based and physics-informed dual-domain networks perform superior to traditional image-only U-Nets in both quantitative fidelity and visual artifact suppression. Conclusions AI-based approaches show promising potential in enhancing CBCT image fidelity by mitigating metal-induced distortions effectively. Despite encouraging results, the broader clinical adoption of such techniques requires standardized evaluation protocols, training models by open-access datasets, and further trials to validate diagnostic impact and generalizability.
Reference Key
openalex_W7162555157 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Parisa Soltani, Pedram Iranmanesh, Fateme Ebrahimzadeh, Francesca Angelone, Alfonso Maria Ponsiglione, Francesco Amato, Amirhossein Moaddabi, Niccolò Giuseppe Armogida, Gianrico Spagnuolo, Carlo Rengo, Hessamoddin Faghihian
Journal dentomaxillofacial radiology
Year 2026
DOI
10.1093/dmfr/twag034
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.