68Ga-DOTA-exendin-4 PET/CT for Insulinoma Localization in Patients with Negative or Inconclusive Conventional Imaging
Clicks: 1
ID: 314667
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #340 of 362 articles by views in the journal of clinical endocrinology & metabolism
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 362 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
CONTEXT: Insulinomas are the main cause of endogenous hyperinsulinemic hypoglycemia (EHH) in adults, with surgery as the only cure. Pancreas-preserving surgery is preferred, making precise preoperative localization crucial. GLP-1R-targeted imaging, such as [68Ga]Ga-DOTA-exendin-4 PET/CT, outperforms other imaging procedures for insulinoma localization. OBJECTIVE: To investigate the performance and clinical impact of [68Ga]Ga-DOTA-exendin-4 PET/CT for the detection of insulinomas in patients with EHH and prior negative or inconclusive conventional imaging. METHODS: In this retrospective, real-world, dual-center imaging study, 101 patients with biochemically proven EHH and/or a positive Whipple's triad underwent [68Ga]Ga-DOTA-exendin-4 PET/CT at two tertiary centers between April 2017 and March 2024. Among these, 58 patients with prior negative or inconclusive conventional imaging constituted the primary analysis cohort. Endpoints: Insulinoma detection rate and sensitivity by [68Ga]Ga-DOTA-exendin-4 PET/CT after negative or inconclusive conventional imaging and impact on clinical management. RESULTS: Among the 58 patients with prior negative or inconclusive conventional imaging, [68Ga]Ga-DOTA-exendin-4 PET/CT was positive in 42 patients, corresponding to a detection rate of 72% (95% CI, 59-83%). Thirty patients subsequently underwent PET/CT-guided surgery. Overall, 32 patients had histological verification (including two PET/CT-negative cases), corresponding to a sensitivity of 93.8% (95% CI, 79-99%). CONCLUSION: In real-world clinical practice, [68Ga]Ga-DOTA-exendin-4 PET/CT provides a high detection rate of 72% for localizing insulinomas, including one case of diffuse nesidioblastosis in patients with EHH and prior negative or inconclusive conventional imaging, thereby enabling PET/CT-guided surgical approaches. These findings underscore the substantial clinical impact of GLP-1R-targeted PET/CT on patient management and prognosis.GLP-1 receptor.
| Reference Key |
openalex_W7162128543
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Julia Fricke, K Laubner, Manuela Schildmeijer, Lea Menz, Camilla Wojsa, Philipp T. Meyer, J Seufert, Damian Wild, Emanuel Christ, Martin T. Freitag |
| Journal | the journal of clinical endocrinology & metabolism |
| Year | 2026 |
| DOI |
10.1210/clinem/dgag214
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.