A dual-channel ratiometric fluorescent probe for determination of the activity of tyrosinase using nitrogen-doped graphene quantum dots and dopamine-modified CdTe quantum dots.
Clicks: 237
ID: 31452
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
66.6
/100
237 views
193 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #55 of 75 articles by views in Mikrochimica acta
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A dual-channel ratiometric fluorometric assay is described for the determination of the activity of the enzyme tyrosinase (TYR). It is making use of blue-emitting nitrogen-doped graphene quantum dots (bQDs) and of red-emitting dopamine-modified CdTe quantum dots (DA-rQDs). A mixture of the two kinds of quantum dots was prepared, with the ratiometric fluorescence intensity of red to blue adjusted to 5:1. The dopamine on the rQDs is catalytically oxidized by TYR to form dopamine quinone, and this leads to a reduction of the intensity of red fluorescence (peaking at 644 nm). The emission of the bQDs (peaking at 440 nm) represents a stable reference signal. After adding different activities of TYR, the color of the fluorescence of the system continuously changes from red to blue. This can also be visually observed. The ratio of luminescence intensities (at 644/440 nm) can be used to quantify the activity of TYR, and the detection limit is 4.5 mU mL. In addition, a test strip is described based on the above method. Graphical abstract Schematic representation of the ratiometric fluorometric method for determination of the activity of tyrosinase (TYR). (The full name of the abbreviation in the Scheme: 1-ethyl-3-[3-(dimethylamino)-propyl] carbodiimide hydrochloride (EDC), dopamine (DA), N-hydroxysuccinimide (NHS), nitrogen-doped graphene quantum dots (bQDs), CdTe quantum dots (rQDs)).
| Reference Key |
qu2019amikrochimica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Qu, Zhengyi;Yu, Tian;Bi, Lihua; |
| Journal | Mikrochimica acta |
| Year | 2019 |
| DOI |
10.1007/s00604-019-3733-x
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.