Advancing morphometric assessment of the aorta and left ventricle from dynamic CT: a deep learning–based study

Clicks: 5
ID: 314264
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #46 of 50 articles by views in European Heart Journal - Imaging Methods and Practice

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Aims Morphometric analysis of the thoracic aorta (TA) and left ventricle (LV) plays a fundamental role in detecting anatomical abnormalities and functional alterations to support preoperative planning, predict disease risk and inform device design. However, conventional approaches to morphometric evaluation are typically performed manually using visualization software, thus resulting in time-consuming, operator-dependent processes that are usually limited to static imaging. This work presents an automated three-dimensional image-based methodological framework for dynamic morphometric analysis, from ECG-gated CT datasets. Methods and results A multi-label 3D U-Net was trained for the automatic segmentation of the TA and LV using a dataset of 50 single-phase CT scans, with ground-truth labelmaps validated under expert radiological supervision. Model performance was tested on an independent multi-phase cohort of 10 patients. The network achieved high segmentation accuracy, with Dice scores of 97.77 ± 0.31% for the TA and 91.45 ± 1.26% for the LV on the multi-phase test set. The resulting 3D surface models enabled the computation of geometric descriptors, including volumetric indices, displacement fields, and centerline-based diameters, across cardiac phases on 42 patients. Overall, the framework demonstrated robustness to variations in contrast intensity, cardiac motion, and inter-patient anatomical variability, providing a reliable and reproducible pipeline for comprehensive, three-dimensional, and time-resolved morphometric analysis of the ventriculo-arterial complex with physiological or mildly altered anatomy. Conclusion This approach has strong potential for future clinical translation, supporting quantitative assessment of cardiac function and aortic pathophysiology.
Reference Key
openalex_W7161753227 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Francesca Dell’Agnello, Katia Capellini, Filippo Cademartiri, Angelo Monteleone, Alessia Gimelli, Simona Celi
Journal European Heart Journal - Imaging Methods and Practice
Year 2026
DOI
10.1093/ehjimp/qyag090
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.