Non-contrast trans-catheter aortic valve implantation using Evolut self-expanding platform: A wire backup technique case report

Clicks: 3
ID: 314248
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #17 of 248 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 248 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Concomitant aortic stenosis and chronic kidney disease (CKD) represent management challenge. Transcatheter aortic valve implantation (TAVI) is an established treatment for patients with symptomatic severe aortic stenosis but requires the use of contrast media, particularly, in patients undergoing self-expanding platform implantation. Therefore, patients with CKD remain at increased risk of developing worsening renal impairment post TAVI. Case summary Herein, we present 62-year-old male patient who was admitted with progressive dyspnoea. His transthoracic echocardiogram revealed severe aortic stenosis and impaired left ventricular systolic function (estimated ejection fraction of 35%). He has background of porcelain aorta and CKD. Despite low-dose contrast CT, the patient’s renal function significantly deteriorated. He was successfully treated with trans-catheter aortic valve implantation using self-expanding valve (Evolut) without the need for contrast media. The procedure was guided by catheter positioning in the non-coronary cusp and wire back-up technique in the left coronary cusp. Conclusion This case demonstrated the feasibility of implanting self-expanding trans-catheter heart valve using Evolut platform without the need for the use of contrast media in a patient at high-risk of worsening renal impairment. The current approach requires good procedural planning and additional vascular access and should be only used in highly selected cases.
Reference Key
openalex_W7161764960 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Krishnarpan Chatterjee, Dr.Mohamed Ali, Mohammad Alkhalil
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag366
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.