Evaluation of a Convolutional Neural Network-Based Artifact Reduction Algorithm for Zirconia Single Crown Artifacts in Cone-Beam Computed Tomography

Clicks: 1
ID: 314088
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #39 of 46 articles by views in dentomaxillofacial radiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
OBJECTIVES: Zirconia-induced artifacts frequently degrade the image quality in dental cone-beam computed tomography (CBCT), and complicate clinical diagnosis. This study aimed to develop and evaluate a novel image-domain artifact reduction algorithm based on convolutional neural networks, named CARNet, specifically for mitigating artifacts caused by zirconia single crowns. METHODS: The CARNet model was architectured on a UNet backbone, enhanced with a dedicated ResASPP module designed for multi-scale feature extraction and fusion via residual and short-cut connections. A dataset was constructed from the public Zenodo clinical repository by simulating zirconia artifacts. Algorithm performance was assessed using both objective metrics-Normalized Mean Absolute Error (NMAE), Structural Similarity Index (SSIM), and Peak Signal-to-Noise Ratio (PSNR)-and subjective evaluation via a Likert scale. CARNet's efficacy was compared against established image-domain algorithms, including ADN and CycleGAN, as well as traditional Linear Interpolation (LI). RESULTS: CARNet processing yielded significantly superior results for zirconia artifacts (axial/occlusal surfaces) than other methods, with NMAE: 0.013 ± 0.001/0.013 ± 0.001; SSIM : 0.959 ± 0.007/0.956 ± 0.008; PSNR: 40.39 ± 0.77/41.41 ± 0.80 dB. Subjective assessments confirmed that CARNet effectively suppressed artifacts while better preserving crown details and marginal integrity. CONCLUSIONS: The CARNet model proves to be an effective and reliable method for reducing zirconia restoration artifacts in CBCT, demonstrating satisfactory performance in restoring images affected by zirconia single crowns.
Reference Key
openalex_W7161634600 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Xieer Ma, Shouwei Zhao, Shuai Hu, Jianxiang Tao
Journal dentomaxillofacial radiology
Year 2026
DOI
10.1093/dmfr/twag028
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.