Electromagnetic interference during Epicardial Ablation in a Patient with an Extravascular Implantable Cardioverter Defibrillator and Arrhythmogenic Right Ventricular Cardiomyopathy: a Case Report

Clicks: 2
ID: 313925
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #75 of 251 articles by views in European Heart Journal - Case Reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 251 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Arrhythmogenic cardiomyopathy (ACM) is an inherited disease characterized by fibrofatty replacement, most often involving the right ventricle but potentially affecting the left or both ventricles. It predisposes to severe ventricular arrhythmia (VA). Differentiating ACM from athlete’s heart remains difficult, particularly in gene-elusive patients. Implantable cardioverter defibrillators (ICD) and catheter ablation are key therapeutic options. Epicardial ablation may be required for VA circuits inaccessible in an endocardial approach, but data on its feasibility in patients with extravascular ICD (EV-ICD) featuring a retrosternal lead is scarce. Case summary A 42-year-old male athlete was admitted for syncope due to sustained ventricular tachycardia (VT) during exertion. Cardiac magnetic resonance imaging (CMR) showed a dilated right ventricle (RV) with wall akinesia and fibrosis involving the RV outflow tract (RVOT). Genetic testing was negative. The diagnosis of borderline gene-elusive ACM was made. An EV-ICD was implanted for secondary prevention. Recurrent sustained VT prompted endocardial and epicardial ablation, which was achievable and successful, but radiofrequency energy application was hampered close to the retrosternal lead due to electromagnetic interference. Conclusion This case highlights the diagnostic and therapeutic challenges of ACM in athletes. Epicardial ablation is feasible even with an EV-ICD, although electromagnetic interference may complicate ablation near the lead. High-level endurance exercise can induce ACM-like remodeling, creating phenotypic overlap with gene-elusive ACM. Early recognition, tailored ablation strategies, and appropriate device therapy are essential for the management of these patients.
Reference Key
openalex_W7160901879 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Matthieu Proust, Feifan Ouyang, Alexander Breitenstein, Firat Duru, Ardan M Saguner
Journal European Heart Journal - Case Reports
Year 2026
DOI
10.1093/ehjcr/ytag340
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.