Successful Coronary Sinus Reducer Implantation in a Patient With a Pre-Existing Left Ventricular Pacing Lead: a Case Report
Clicks: 1
ID: 313516
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #192 of 251 articles by views in European Heart Journal - Case Reports
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 251 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract Background Coronary sinus reducer (CSR) implantation offers symptomatic relief in patients with refractory angina who remain symptomatic despite optimal medical therapy and repeated revascularization procedures. Pre-existing coronary sinus pacing leads can complicate device delivery and raise concerns about lead displacement or venous injury. Case Summary A 77-year-old man with ischaemic heart failure (left ventricular ejection fraction 33%), a cardiac resynchronization therapy defibrillator (CRT-D; upgraded from a previously implanted implantable cardioverter-defibrillator) and Canadian Cardiovascular Society Class III refractory angina after extensive revascularization was evaluated for alternative treatment. Despite multiple interventions addressing recurrent in-stent restenoses, disabling angina persisted, prompting referral for CSR implantation. Right internal jugular venous access was selected for favourable coronary sinus alignment, with ultrasound guidance and use of an extrastiff guidewire and selective venography to delineate anatomy. Advancement of the 12 Fr delivery sheath was impeded by a prominent Thebesian valve; a 5 mm balloon was inflated at the obstruction and then partially inflated to facilitate “balloon-assisted tracking,” enabling safe sheath passage without injuring the venous wall or disturbing the left ventricular lead. The CSR was deployed in the mid-distal coronary sinus with stable pacing parameters and no immediate procedural complications. During follow-up the patient remained free of angina. Discussion This case demonstrates technical feasibility and safety of CSR implantation in the setting of a pre-existing left ventricular pacing lead and challenging venous anatomy when meticulous access selection, balloon-assisted tracking, angiographic confirmation, and systematic monitoring of lead electrical parameters are employed.
| Reference Key |
openalex_W7161172592
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Marco Ciardetti, Michele Coceani, Augusto Esposito, Alberto Aimo, Cataldo Palmieri |
| Journal | European Heart Journal - Case Reports |
| Year | 2026 |
| DOI |
10.1093/ehjcr/ytag356
|
| URL | |
| Keywords | Keywords not found |