High-Resolution Breast Cancer Detection Using AOA-Optimized mm-Wave Antenna and GRU Classifier
Clicks: 1
ID: 312674
2025
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #171 of 705 articles by views in Journal of Computing & Biomedical Informatics
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 705 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Breast cancer detection at an early stage remains an open challenge due to limitations in the resolution, cost, and portability of conventional imaging systems. This paper presents a high-resolution framework for breast cancer detection by integrating an Angle-of-Arrival-optimized millimeter-wave antenna with an intelligent deep-learning classifier. The antenna design is optimized using an evolutionary MAOA optimization algorithm to enhance directional gain, penetration capability, and spatial resolution, allowing for better localization of malignant tissues within heterogeneous breast phantoms. Backscattered mm-wave signals are preprocessed and input to a GRU-based neural classifier that learns temporal-spectral features associated with the presence of tumors. Experimental simulation and prototype measurements of the proposed system demonstrate superior detection accuracy with reduced false-positive rates and improved resolution compared with other millimeter-wave and microwave imaging approaches. The integration of optimized antenna design with a sequence-aware GRU model presents a promising pathway toward the realization of noninvasive, compact, and highly reliable breast-cancer screening technologies.
| Reference Key |
imported_1777055953_69ebb8d12a640
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | R G Vidhya |
| Journal | Journal of Computing & Biomedical Informatics |
| Year | 2025 |
| DOI |
10.56979/1001/2025/1152
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.