Hybrid GAN-Augmented Multi-Modal Medical Imaging Framework with Squeeze-and-Excitation CNN for Robust Classification

Clicks: 1
ID: 312664
2025
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #612 of 705 articles by views in Journal of Computing & Biomedical Informatics

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 705 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A hybrid GAN architecture was designed to solve multi-modal medical image synthesis and disease classification by combining key architectural principles from DC-GAN, Conditional GAN, and SR-GAN, thereby enhancing training stability, providing label-conditioned image synthesis, and improving perceptual image quality. The proposed framework was extensively tested on large, diverse medical imaging datasets, including chest X-ray images to identify pneumonia, retinal fundus images to evaluate diabetic retinopathy, brain MRI images to detect tumors, microscopic images of leukemia white blood cells, and dermoscopic images to analyze skin cancer. Quantitative experimentation revealed a steady convergent behavior, the values of the generator loss and discriminator loss continued to decline throughout each of the datasets and the lowest values were found in diabetic retinopathy cases (generator loss of 0.522 and discriminator loss of 0.425) and leukemia cases (generator loss of 0.285 and discriminator loss of 0.224), maintaining the presence of diagnostically significant pathological features. Computational efficiency was also high, with about 0.75 hours of training time and a relatively small number of 0.67 million parameters, compared to SR-GAN-based models that require more than 10 hours of training time and more than 2.3 million parameters. The success of the framework was also confirmed by the quality of the generated images, attaining a high signal-to-noise ratio of 36.742, structural similarity index of 0.93, and Fréchet inception distance of 30.402, which is better than several other recent state-of-the-art methods, such as DRForecastGAN, GAN-VSP, IFGAN, and Pix2Pix GAN. Also, incorporating a Squeeze-and-Excitation convolutional neural network classifier not only led to a significant boost in disease classification performance but also improved the accuracy of diabetic retinopathy and pneumonia to 0.90 and 0.98, respectively. In general, the suggested hybrid GAN model has great potential as a low-cost, high-quality solution for medical image generation, data augmentation, and automated disease detection in clinical decision-support systems.
Reference Key
imported_1777055886_69ebb88e4df71 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Ashwin Makwana
Journal Journal of Computing & Biomedical Informatics
Year 2025
DOI
10.56979/1001/2025/1182
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.