Feasibility study of portable microwave microstrip open-loop resonator for non-invasive blood glucose level sensing: proof of concept.
Clicks: 331
ID: 31239
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
77.0
/100
331 views
234 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #10 of 14 articles by views in Medical & biological engineering & computing
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Self-management of blood glucose level is part and parcel of diabetes treatment, which involves invasive, painful, and uncomfortable methods. A proper non-invasive blood glucose monitor (NIBGM) is therefore desirable to deal better with it. Microwave resonators can potentially be used for such a purpose. Following the positive results from an in vitro previous work, a portable device based upon a microwave resonator was developed and assessed in a multicenter proof of concept. Its electrical response was analyzed when an individual's tongue was placed onto it. The study was performed with 352 individuals during their oral glucose tolerance tests, having four measurements per individual. The findings revealed that the accuracy must be improved before the diabetes community can make real use of the device. However, the relationship between the measuring parameter and the individual's blood glucose level is coherent with that from previous works, although with higher data dispersion. This is reflected in correlation coefficients between glycemia and the measuring magnitude consistently negative, although small, for the different datasets analyzed. Further research is proposed, focused on system improvements, individual calibration, and multitechnology approach. The study of the influence of other blood components different to glucose is also advised. Graphical abstract.
| Reference Key |
juan2019feasibilitymedical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Juan, Carlos G;García, Héctor;Ávila-Navarro, Ernesto;Bronchalo, Enrique;Galiano, Vicente;Moreno, Óscar;Orozco, Domingo;Sabater-Navarro, José María; |
| Journal | Medical & biological engineering & computing |
| Year | 2019 |
| DOI |
10.1007/s11517-019-02030-w
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.