The Role of 18F-Fluorodeoxyglucose Positron-Emission Tomography/Computed Tomography in the Diagnosis of Postoperative Hardware-Related Spinal Infections.
Clicks: 324
ID: 31232
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
67.1
/100
324 views
245 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #3 of 8 articles by views in the israel medical association journal : imaj
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Implant-related spinal infections are a surgical complication associated with high morbidity. Due to infection, hardware removal may be necessary, which could lead to pseudarthrosis and the loss of stability and alignment.To evaluate the accuracy and diagnostic value of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG PET/CT) in the workup of patients with suspected implant-related infections of the spine and to assess the clinical impact of PET/CT results on the management of these infections.The study included nine consecutive patients with a history of spinal surgery who underwent PET/CT for evaluation of suspected spinal implant related infection. All imaging studies were performed between January 2011 and December 2013. All 18F-FDG PET/CT scans were performed on an 8 slice PET/CT following an 18F-FDG injection. Images were scored both visually and semi-quantitatively by a radiology expert. Results were compared to additional imaging studies when available, which were correlated to clinical and bacteriological findings allowing calculation of sensitivity, specificity and accuracy.Among the patients, five experienced hardware-related spinal infection. 18F-FDG PET/CT sensitivity was 80%, specificity 100%, and accuracy 88.9%. One scan produced a false negative; however, a second PET/CT scan revealed an infection.PET/CT was found to be valuable for the diagnosis of postoperative hardware-related spinal infection, especially when other imaging modalities were uninformative or inconclusive. As such, PET/CT could be useful for management of infection treatment.
| Reference Key |
frenkel-rutenberg2019thethe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Frenkel Rutenberg, Tal;Baruch, Yuval;Ohana, Nissim;Bernstine, Hanna;Amitai, Amir;Cohen, Nir;Domachevsky, Liran;Shemesh, Shai; |
| Journal | the israel medical association journal : imaj |
| Year | 2019 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.